Pt.1 Ch.1 General Regulations
Main changes coming into force 1 January 2007

Sec.2 Scope of Rules and Class Notations

  • In Sec.2 Table B32 concerning the class notation NAV-O, the restriction “constructed before 1 July 2002” has been removed.

  • In Sec.2, a new Table B40 has been added covering owner/managers’ Planned Inspection and Maintenance System for hull and the new class notation PIMS (HULL).

Pt.3 Ch.1 Hull Structural Design, Ships with Length 100 metres and above
Main changes coming into force 1 July 2007

Sec.16 Fatigue Control

  • The requirements have been changed to reflect current approval procedure, ensure a common understanding and enhance the transparency of the rules.

  • The current rules assume that the coating in ballast tanks is effective for 15 years with a normal vessel design life of 20 years. The amended rules clarify how to apply this assumption in case the design life is specified beyond the standard 20 years.

Significant editorial changes:

General

  • The material factor f1 for NV-40 steel has been changed from 1.43 to 1.47 throughout the chapter to align with IACS common structural rules for tankers and bulk carriers.

Sec.2 Materials and Material Protection

  • Table B1 and Table B2 have been modified to align the rules’ thickness of material limits and related minimum material grades, according to IACS UR S6, with the existing material requirements in Pt.2 Ch.2 Sec.1.

  • Table B1 has also been modified with provisions covering thicknesses of more than 50 mm.

Pt.3 Ch.2 Hull Structural Design, Ships with Length less than 100 metres
Significant editorial changes

General

  • The material factor f1 for NV-40 steel has been changed from 1.43 to 1.47 throughout the chapter to align with IACS common structural rules for tankers and bulk carriers.

Sec.2 Materials and Material Protection

  • Table B1 and Table B2 have been modified to align the rules’ thickness of material limits and related minimum material grades, according to IACS UR S6, with the existing material requirements in Pt.2 Ch.2 Sec.1.

  • Table B1 has also been modified with provisions covering thicknesses of more than 50 mm.

  • Sub-section element B400 has been re-numbered B500 and vice versa. Previous item B502 has been deleted.

Pt.3 Ch.3 Hull Equipment and Safety
Significant editorial changes

General

  • The material factor f1 for NV-40 steel has been changed from 1.43 to 1.47 throughout the chapter to align with IACS common structural rules for tankers and bulk carriers.

Sec.2 Sternframes, Rudders and Steering

  • Sec.2 Table B1, Sec.3 Table F3 and Sec.4 Table B1 have been modified to align the rules’ thickness of material limits and related minimum material grades, according to IACS UR S6, with the existing material requirements in Pt.2 Ch.2 Sec.1.

  • Under Sec.2 item A301, “outline of the propeller” has been removed from the first list item and added as first list item in A304. The reason is that the outline of the propeller is only used to evaluate the clearance guidance given in C105 and is not subject to approval.

Pt.4 Ch.2 Rotating Machinery, General
Main changes coming into force 1 July 2007

Sec.4 Electric Power Generation

  • Sec.4 has been amended to align with IACS UR M3 for emergency generator sets.

Pt.4 Ch.3 Rotating Machinery, Drivers
Main changes coming into force 1 July 2007

Sec.1 Diesel Engines

  • In item A501, foundations of diesel engines are now considered as the engine manufacturers design responsibility.

  • In item A601, the scope of torsional vibration calculations for diesel driven installations has been clarified.

  • In item I301, the scope for sea trial of diesel propulsion engines driving fixed pitch propellers has been amended to be in line with IACS UR M51.

  • Item I302 concerning the requirement for vibration measurement of turbochargers during sea trial has been deleted.

  • In Table E3 row no. 9, covering crankcase explosive condition, has been modified to be in line with IACS UR M63.

Pt.4 Ch.4 Rotating Machinery, Power Transmission
Significant editorial changes

Sec.1 Shafting

  • In Table B1 the safety factor for low cycle criteria has been changed. The new safety factor will be 1.25 for both peak stresses and reversed stresses in notches. The justification for a lower safety factor was that the low cycle fatigue criterion was too strict; in that the scatter in material properties for low cycle fatigue is essentially smaller than for high cycle fatigue. The consequence of this change is slightly reduced shaft diameters in plants with low torsional vibration levels.

  • Concerning item B206. The factor in the formula for low cycle criterion has been changed from 29 to 28. This is consistent with the new reduced safety factor shown in Table B1. In Table B2 the k1-factor for longitudinal slot in oil distribution shafts has been changed in order to match the corrected formula for stress concentration factor (based on an extensive FE parameter study).

  • Concerning item B207. The factor in the formula for low cycle criterion has been changed from 29 to 28. This is consistent with the new reduced safety factor shown in Table B1. In Table B4 factors k1 for low cycle criteria have been changed based on updated knowledge on stainless martensitic or duplex steels.

  • Concerning item B402. In the full speed range TC1 has been changed from "torque" to "required torque", in order to make the text more clear (i.e. the use of partial safety factors directly on the load). The Formula for thrust capacity has been removed and a new formula for axial force, FA, has been added. The reason being that the previous partial safety factor on thrust actually slightly reduced the requirement for friction torque. The formula for friction force, FFR, has been corrected (previous misprint) and the formula for surface pressure, p, has been modified in order to take into account the corrected axial force. The formula for pull-up distance has also been corrected from a previous misprint.

  • Concerning item B403. In the full speed range TC1 has been changed from "torque" to "required torque", in order to make the text more clear (i.e. the use of partial safety factors directly on the load). The formula for thrust capacity has been removed and a new formula for axial force, FA, has been added. The reason being that the previous partial safety factor on thrust actually slightly reduced the requirement for friction torque. The formula for friction force, FFR, has been changed and the formula for surface pressure, p, has been modified in order to take into account the corrected axial force. The formula for maximum permissible surface pressure, pmax, has been corrected from a previous misprint. The consequence on required pull up length is minor, a small increase for pushing propellers and a small decrease for pulling propellers. No consequence for direct coupled 2-stroke plants.

  • Concerning item B501. A new requirement (secure against axial movement) for tapered connections steeper than 1:30 and keyed connections with axial forces, has been added.

  • Concerning item C103. This rule requirement has been removed, as it gives little added value to bearings and seals.

Pt.4 Ch.5 Rotating Machinery, Driven Units
Main changes coming into force 1 July 2007

Sec.1 Propellers

  • Sub-section element A200: Documentation requirements have been clarified - design parameters that should be specified have been itemized. An assembly drawing for built-up propellers has been included in the table of documentation requirements.

  • Sub-section element B100: A correction in guidance note for fatigue testing of propeller materials has been performed.

  • Sub-section element B200: The background for the chosen safety factors has been described.

  • Sub-section element B300: The part related to design requirements for hub and pitch mechanism has been significantly clarified, explaining the principles in more detail. Minimum safety factors for static and fatigue calculations have been given, and their background has been described. Reference has also been given to CN 41.5, where even more details are to be found. A paragraph ensuring a minimum hub thickness for “thin-hub” shrink fitted propellers has also been included.

  • Sub-section element C100: Inspection requirements for propeller blades have been specified in more detail.

  • Sub-section element H200: Verification of proper securing of bolts for fitting of propeller and propeller blade has been addressed.

Sec.3 Podded and Geared Thrusters

  • The limit for not requiring torsional vibration calculations for auxiliary thrusters has been set to 500 kW, as for other auxiliary installations (Table A1).

  • Requirement for vibration measurement of turbochargers during sea trial has been deleted.

  • Design criteria for azimuth speeds of propulsion thrusters have been amended.

  • Harmonised power limit has been introduced for when torsional vibration calculations are unnecessary for auxiliaries.

  • In Table E1, several corrections mainly covering the use of footnotes have been made.

Significant editorial changes
Sec.1 Propellers

  • The Guidance note in item C301 has been deleted and a new item C302 has been added.

Sec.2 Water Jets

  • Item A202, covering requirements for torsional shock vibration calculations, has been removed.

  • The Guidance note in item C201 has been deleted and a new item C203 has been added.

  • Item I105 has been modified for clarification.

Pt.4 Ch.7 Boilers, Pressure Vessels, Thermal-Oil Installa­tions and Incinerators
Main changes coming into force 1 January 2007

Sec.8 Manufacture, Workmanship and Testing

  • In Sec.8 item D106, a new paragraph, covering ultrasonic testing in lieu of radiographic testing, has been added.

Pt.4 Ch.8 Electrical Installations
Significant editorial changes

Sec.1 Service Description

  • A103 b): Date of request for valid standard has been changed from class request to date of contract between owner and yard.

  • A103 c): Deleted.

  • Table B1: Clarification of documentation requirements for EX installations. Additional information element: Capacity of battery and charger for battery systems.

  • B303 and Table B9 note 1: DNV Product certificate or DNV Type Approval certificate required according to Table B9, work certificate required when necessary for further information.

  • B304 GN deleted.

  • B403 b) deleted.

  • B404: Added "cable routing arrangement" to list of available documentation.

  • Table B8: Clarification of documentation requirements for system for automatic start/stop of generators and automatic operation of breakers.

  • Table B9: The certification limit for semi-conductor assemblies for power supplies has been changed from 100 kVA to 50 kVA.

Sec.2 System Design

  • A102 b): Text concerning equipment location has been deleted.

  • A103 f): Clarification of requirements for TN-C-S system has been added.

  • A106 Text concerning systems on tankers has been deleted.

  • A204: Voltage tolerance for battery systems has been changed in line with IACS UR E5.

  • B104 a) and c): Clarification of requirements for automation system.

  • B105 Text concerning stand-by start has been added.

  • E102 b): The requirement for staring of the engine for the emergency fire pump has been deleted.

  • F103: References have been updated.

  • F202, 203 and 204: COLREG, as a common term, has been added to navigation lights. F204 c) updated to be in line with IACS UI COLREG2.

  • F301 f) Text concerning high voltage shore connection has been deleted.

  • F401 a) The scope of supply to navigation equipment has been changed in line with 1A1/SOLAS/IACS requirements.

  • G103: f) has been moved to G600.

  • G201: f) has been moved to G202 and h) has been moved to H101.

  • G401 c): has been deleted.

  • G501 d): Rule references have been updated.

  • New H200: G201 h) moved to H200 concerning requirements about general control.

  • H303 b) (previous H203): Text concerning the acceptance of one independent synchronising device for each generator has been added for clarification.

  • H500 (previous H400): Equipment requiring emergency stop has been updated in line with SOLAS. Requirement for separation of control cables and control circuits for duplicated equipment has been added.

  • I206 This item, concerning hazardous areas, has been deleted.

  • I301 c): Text concerning fittings for installation above generators, has been amended.

  • I400 Table I1: The table has been divided in two tables: one for vented types and one for dry types. The limit for battery size located in electrical assemblies has been increased to 5kVAh. When the assembly is mechanically ventilated the upper limit for installation in the battery room has been increased to 100 kVAh.

  • I403 b) Text concerning the acceptance of less distance above each cell, provided disconnection and maintenance can be carried out safely, and that cooling of the batteries has been taken into account, has been added.

  • I403 d) is made applicable for GMDSS batteries not installed in accordance with b.

  • I403 e) has been deleted as it is covered by new tables.

  • I500: Deleted I501 d), based on feedback from surveyors, and as this requirement is DNV speciality. Redundancy requirements for generator, steering gear and transformer cables are covered by 502 and 503.

  • J201: Text concerning PVC 60°C temperature class has been deleted as PVC insulation temperature class has been changed to 70°C in line with IEC 60092-350.

  • J701: Added new c): Concerning the neutral conductor that shall normally be a part of the power supply cable. Separate neutral cable may be accepted if the power cable not is provided with magnetic braiding.

  • J802: Rating of cables with temperature class 70°C has been added.

Sec.3 Equipment in General

  • C102: Text concerning battery systems has been updated in line with IACS UR E5.

Sec.4 Switchgear and Controlgear Assemblies

  • A101 a): Reference to IEC 60466 has been deleted.

  • A105 b) Text concerning arrangements without flame retardant partitions has been added.

  • A107 b) has been rewritten. Old item a), b) and c) are covered by the new b), c) and d). Old d) has been deleted as this requirement is covered by Sec.3 E104 a). Sub-item e) is a new requirement for indication of correct setpoint of protection. This requirement is based n SOLAS Reg. II-1/45.6.2).

  • A108: IEC 60947-4-1 Part 4 has been deleted and replaced with IEC 60437-1 Table 14 and 16, pollution degree 3, inhomogeneous field.

  • B106 b): Text concerning the arrangement of switches rated more than 63A shall be accessible on the switchboard front, has been deleted.

  • B108 moved to new B200 (previous B300).

  • B109 (new B108) Text has been rewritten and the Guidance note incorporated in the new text.

  • B200 has been deleted as covered by Sec.2 I400.

  • C101 and C105: References have been updated.

  • D106: New c) has been added concerning impulse voltage test in accordance with IEC 60439-1 section 8.3.2. d) and e) have been moved to guidance note.

Sec.5 Rotating Machines

  • Sec.5 has been updated in line with IEC 60034.

  • A203: The text has been amended concerning increased temperature rise, where water cooled heat exchangers are used. Corrected from 8°C to 13°C.

  • Table A1: Temperature rise for insulation class F has been updated in line with IEC 60034-1.

  • References have been updated in item A204 b), Table C1 and associated guidance notes.

Sec.6 Power Transformers

  • A101: IEC reference has been amended to IEC 60076.

  • A201: Text concerning the acceptance of autotransformers used for feeding/supplying single consumers has been added in line with today's practices.

  • B100: Text concerning the requirements for testing of dry transformers in line with IEC 60076-11 as follows:

  • Short circuit test is according to IEC considered as a special test.

  • Inducted AC withstand voltage test (IEC 60076-11 20) has been added.

  • Partial discharge measurement≥ 3.6 kV (IEC 60076-11 22) has been added.

Sec.7 Semi-conductor Converters

  • Sec.7 has been rearranged and rewritten. The new requirement is in line with the IEC 61800 series for semi-conductor converters for motor drives and IEC 62040 series for semi-conductor converters for power supply.

Sec.8 Miscellaneous Equipment

  • A101 e). Text has been added concerning exceptions from earthing of socket outlets made valid for IT system only.

Sec.9 Cables

  • Table B1: Temperature class for PVC has been changed to 70 °C (IEC 60092-351).

  • The following Note has been added: "Silicon rubber only to be used together with a varnished glass braid due to pure mechanical properties". (IEC 60092-376).

  • H101: References updated according to IEC 60092-350.

Sec.10 Installation

  • C503 c): Requirement for 4 mm thickness has been deleted.

  • C505: Requirement for fixing distance of electrical cables in accordance with IEC 60322-3 has been deleted as covered by Table C3.

  • C703: Wall thickness of cable pipes has been replaced with a reference to Pt.4 Ch.6 Sec.6 Table A1, A2 and A2.

  • C904 Guidance note: Added "(metal to metal without paint or coating)".

  • D409: New item concerning test requirement of semi-conductor converters after installation.

Sec.11 Hazardous Area Installations

  • C101 d) Added reference to IEC 60092-502, with regards to temperature class and gas group.

  • C205: Updated with requirements from Sec.2 I400. Collection of requirement for hazardous area with regard to batteries.

Pt.5 Ch.1 Ships for Navigation in Ice
Main changes coming into force 1 January 2007

Sec.1 General Requirements

  • In Table A1, a new row has been added covering DAT(-X°C).

Sec.4 Vessels for Arctic and Ice Breaking Service

  • A new item A506 has been added covering documentation for stability and watertight integrity.

  • Item J404 has been modified for clarification. For the same reason, a new item J107 has been added. The items cover among others a new illustration and Guidance note.

Sec.6 Winterization

  • Item C102 and C203 have been corrected.

Main changes coming into force 1 July 2007

Sec.1 General

  • The changes cover the implementation of IACS UR I1 and the Finnish Maritime Authority's (FMA) new definition of the maximum and minimum ice class draughts and marking of ice draught when limited below the maximum "Summer Fresh water" line.

  • The definitions of LWL and BWL have been replaced throughout by the new definitions of upper and lower ice water lines, i.e. UIWL and LIWL, respectively.

Sec.1 General Requirements
A new sub-section D has been introduced: '

  • Parts of the text in Sec.3 A302 have been moved to new item D101. The first paragraph has been made valid for all ice class notations.

  • New item D102 covers how any limitation of ice class draught compared to maximum "Summer Fresh water" draught shall be given in the ice class notation, and how ship sides shall be marked.

Sec.3 Ice Strengthening for the Northern Baltic

  • Revised definitions have been incorporated in line with the UR I1 and the FMA's new definitions.

Pt.5 Ch.2 Passenger and Dry Cargo Ships
Significant editorial changes

General

  • The material factor f1 for NV-40 steel has been changed from 1.43 to 1.47 throughout the chapter to align with IACS common structural rules for tankers and bulk carriers.

Pt.5 Ch.4 Chemical Carriers
Main changes coming into force 1 January 2007

Sec.11 Fire Protection and Extinction

  • Under Sec.11, in item B206 the last paragraph has been amended to cover documentation requirements for foam characteristics.

Pt.5 Ch.5 Liquefied Gas Carriers
Main changes coming into force 1 January 2007

General

  • The concept of Gas Safe/Dangerous Zones and Spaces has been replaced by Non-hazardous/Hazardous Areas of Zone 0, 1 and 2. This has mainly affected Sec.1 "General Requirements", Sec.3 “Damage Stability and Ship Arrangements”, Sec.10 "Mechanical Ventilation in the Cargo Area" and Sec.12 "Electrical Installations", which have been revised accordingly.

Sec.10 Mechanical Ventilation in the Cargo Area

  • This section has been re-arranged for clarification and in order to align with Oil Carriers (Pt.5 Ch.3) and Chemical Carriers (Pt.5 Ch.4) wherever possible.

Sec.11 Fire Protection and Extinction

  • Requirements for structural fire protection have been removed.

Sec.12 Electrical Installations

  • In this section, the specification of permitted types of electrical equipment in the different Gas Dangerous Zones and Spaces has been replaced by area classification of typical spaces and reference to Pt.4 Ch.8 Sec.11 "Hazardous Areas Installations" for selection of equipment. Pt.4 Ch.8 Sec.11 has previously been revised with regard to the concept of Hazardous Area Zones.

Pt.5 Ch.7 Tugs, Supply Vessels and Other Offshore/Harbour Vessels
Significant editorial changes

Sec.3 Supply Vessels

  • Under Sec.3 item B204, the acceptable equivalent stress level has been corrected from 235 N/mm2 to 200 N/mm2.

Under Sec.3 item B208, the second paragraph has been corrected so that scantlings of foundation and supports of stern roller shall be based on 2 times the working load (not 3 times).

Pt.6 Ch.1 Miscellaneous Notations
Main changes coming into force 1 January 2007

General

  • The material factor f1 for NV-40 steel has been changed from 1.43 to 1.47 throughout the chapter to align with IACS common structural rules for tankers and bulk carriers.

Pt.6 Ch.3 Periodically Unattended Machinery Space
Significant editorial changes

Sec.1 General Requirements

  • In item C101 documentation requirements have been clarified.

Sec.3 Class Notation E0

  • Table A1 through A7 have been brought in line with the corresponding tables of the machinery rules (Pt.4).

Pt.6 Ch.9 Loading Computer Systems (LCS) for Stability and Longitudinal Strength
Main changes coming into force 1 January 2007

Sec.3 Certification

  • Under Sec.3, in item A206 the last sentence has been deleted and item A208 has been deleted in its entirety. The subsequent items have been re-numbered accordingly. The reason for the change is that specification of the content of the loading computer certificate is no longer considered necessary.

Pt.6 Ch.12 Environmental Class
Main changes coming into force 1 January 2007

Sec.1 General Requirements

  • Under Sec.1, item B407 and under Sec.3, item B202 the reference to US EPA has been removed. This reference has become erroneous since it gives emission levels not only as a function of NOx, but as a combination of NOx and HC (hydrocarbons).

Pt.6 Ch.13 Gas Fuelled Engine Installations
Main changes coming into force 1 July 2007

Sec.1 General

  • The applicability of the DNV rules for LNG carriers, fitted with gas engines, has been clarified. For those parts of the rules that are relevant to LNG carriers, a system utilising bold italic print, of what is not relevant, has been introduced.

3.1 General Requirements

Sec. 3 Arrangement and System Design

Sec. 5 Electrical Systems

  • The new IEC 60092-502 standard for gas dangerous zones has been adopted by IMO and will be implemented in the DNV rules for new tankers, in January 2007. The standard utilises gas zones 0, 1 and 2 instead of "gas dangerous" as previously used. The definitions as well as the electrical and ventilation requirements in Pt.6 Ch.13 have therefore been updated to be in line with the new standard.

Sec.1 General Requirements

  • New item A102, concerning applicable gases, has been included to make it clear that additional consideration may be necessary if gases with different properties, other than natural gas (methane), are to be used as fuel. These gases may be heavier than air, or with higher leakage rates, such as propane and hydrogen.

Sec. 3 Arrangement and System Design

  • Concerning item B103. Access to the tank room is normally not to be open for passage during normal operation, this is to stop people entering the tank room. Therefore a requirement for the gas tank room, not to be accessible during normal operation, has been added.

  • Concerning item D201. For low pressure gas systems ventilation inlet openings for the double wall piping or duct can be accepted located in the engine room on the condition that a gas detection system is fitted in the engine room. This is similar to what is already done in LNG tankers with dual fuel boilers.

  • Concerning item E104. The design pressure for outer boundary around low pressure piping, has been changed from design pressure (10 bar) to actual working pressure of inner pipe. This has been changed to make it possible to use rectangular ducts and not only piping as outer boundary.

Sec.6 Control, Monitoring and Safety Systems

  • Concerning item C101. Gas detection requirements have been updated. A requirement for two independent gas detection systems, in ESD protected engine room spaces, has been added, since this update is found to provide a correct level of safety.

  • Concerning item C103. In line with ABS rules as well as draft proposal for an International Code for Gas Fuelled Engine Installations (IGF). A requirement for analysis or testing to verify the correct location of gas detectors is also added.

  • Concerning item B102 (deleted). The requirement for temperature monitoring of gas tanks has been deleted. This was found unnecessary for small gas tanks as these are used for gas bunker.

Sec.7 Compressors and Gas Engines

  • Concerning item B104. A requirement for explosion relief venting or explosive strength of the inlet air manifold, where gas is mixed with air via a common inlet manifold has been moved from section for gas-only engines to the general section to ensure that this important requirement also covers dual fuel engines.

Pt.6 Ch.16 NAV-O Class Notation
Main changes coming into force 1 January 2007

General

  • The main structure of this chapter has been left unchanged. Some of the text has been removed or amended in order to clarify the requirements, such as:

    • the previous limitation that the NAV-O notation can only be given to vessels constructed before 1 July 2002 has been removed

    • equirements for added documentation to be submitted for information have been included.

Pt.7 Ch.1 Survey Requirements
Main changes coming into force 1 January 2007

Sec.1 General Requirements

  • Sub-section element B200 “Hull ISP (Integrated Survey Programme)” has been deleted to align with IACS PR 33 and replaced by a new class notation PIMS (HULL). The related requirements have been placed in new Sec.7 D.

  • In Table A1, a row covering the new class notation PIMS (HULL) has been added.

Sec.7 Optional Class Notation Surveys

  • Sub-section B “RATE(A) - Rating and Enhanced Technical Standard” has been amended as follows:

    The technical requirements for oil tankers are made applicable to container ships as well, except for the requirement to have a Condition Assessment Programme (CAP) from the third Renewal Class Hull (RCH) survey.

Significant editorial changes

Sec.1 General Requirements

  • In Table A1, twelfth row, “HMON-1 or HMON-2” has been replaced by HMON(...).

Pt.8 Ch.1 Common Structural Rules for Double Hull Oil Tankers with Length 150 metres and above
Main changes coming into force 1 April 2007

Sec.6 Materials and Welding

  • Table 6.3.1 has been amended covering corrosion addition for heated cargo tanks.

Sec.8 Scantling Requirements

  • Item 1.1.2.2 has been amended to avoid misunderstanding of whether the heavy ballast condition as specified in the Common Structural Rules is an operational condition. Trim requirement has been added.

  • Item 1.4.2.6 has been amended to cover an increase of the buckling utilisation factor to 0.9.

  • Item 1.4.2.8 has been amended to cover an increase of the buckling utilisation factor to 0.9.

Sec.9 Design Verification

  • Table 9.2.1 has been amended with respect to allowable yield utilisation for tight floors, girders and webs.

Sec.10 Buckling and Ultimate Strength

  • Table 10.2.1 has been amended covering an increase in the slenderness coefficient for bulb profiles.

Sec.11 General Requirements

  • Item 3.1.4.14 has been amended to allow for full penetration welds using a small root face of 3 mm and deep penetration welding procedures.

Sec.12 Ship in Operation Renewal Criteria

  • Table 12.1.2 has been amended to cover additional corrosion for heated cargo tanks to boundaries between heated cargo oil tanks and ballast tanks.

Appendix C - Fatigue Strength Assessment

  • Figures C.2.2 and Figure C.2.3 have been amended such that building tolerance is in line with acceptable ship building tolerances specified in IACS Recommendation 47.

>>